LATITUDE Patient Management system

 

= Yellow Alert
= Red Alert
  Tachy Devices CRT Devices
                         
VITALITY HE
VITALITY HE VITALITY 2 VR VITALITY 2 DR VITALITY DS VR VITALITY DS DR PRIZM 1 VR PRIZM 1 DR RENEWAL 3/4 & RF
Battery
Device battery has reached Elective Replacement Indicator (ERI)                        
Device battery has reached End of Life (EOL)                        
Voltage was too low for projected remaining capacity                        
Explant Indicator reached                        
Remote Monitoring disabled due to limited battery capacity                        
Shock Lead
Low shock lead impedance                        
High shock lead impedance                        
Low shock lead impedance detected when attempting to deliver a shock                        
High shock lead impedance detected when attempting to deliver a shock                        
Tachy Mode
V-Tachy Mode changed due to magnet                        
V-Tachy Mode set to value other than Monitor + Therapy                        
Venticular Pacing Leads
Low right ventricular pacing lead impedance                        
High right ventricular pacing lead impedance                        
Low right ventricular intrinsic amplitude                        
High right ventricular intrinsic amplitude                        
Low left ventricular intrinsic amplitude                        
High left ventricular intrinsic amplitude                        
Low left ventricular pacing lead impedance                        
High left ventricular pacing lead impedance                        
Atrial Pacing Leads (Dual-chamber devices only)
Low atrial intrinsic amplitude                        
High atrial intrinsic amplitude                        
Low atrial pacing lead impedance                        
High atrial pacing lead impedance                        
Arrhythmias
Shock therapy delivered to convert arrhythmia (Ventricular)                        
Accelerated arrhythmia episode (Ventricular)                        
Atrial Arrhythmia Burden in a 24 hour period
(Dual- chamber devices only)
                       
Patient triggered event stored                        
Pacing
Right Ventricular pacing                        
Cardiac Resynchronization Therapy Pacing                        
High Voltage Detected on Shock Lead During Charge                        
Therapy history corruption detected                        
Possible Device Malfunction                        
Device Parameter Error                        
Weight
Weight gain of at least 5 lb. in a week or at least 2 lb. average over a two or more day period                        
Weight loss of at least 5 lb. in a week or at least 2 lb. average over a two or more day period                        